Stator Partial Discharge Monitoring
Partial discharge monitoring provides information on the small electrical sparks that occur within the insulation as a result of aging or deterioration. Iris Power solutions help plan maintenance requirements prior to insulation failure and shorts. read more»
Stator End-Winding Vibration Monitoring
Stator End-Winding vibration caused by loosening of the windings and thermal cycling can lead to fracturing of the copper conductors in the windings or faults due to insulation wearing. Iris Power solutions provide information on the location and severity of end-winding vibration in order for corrective actions. read more »
Stator Wedge Tightness Testing
Loose stator wedges can lead to coil vibration and erosion of stator insulation. Iris Power stator wedge tightness testing provides a consistent and quantitative means of identifying the location and severity of loose stator wedges in order to plan rewedging or other necessary repairs.
Rotor Core Shorted Turn Detection for Synchronous Motors
Rotor magnetic flux variations are the result of the degradation of the rotor winding insulation by mechanisms like load cycling, thermal aging and contamination. Iris Power provides solutions for measuring the magnetic flux to determine if rotor winding shorts have occurred in order to plan maintenance requirements. read more»
Stator Core Lamination Integrity Testing
Stator core lamination integrity can be degraded through thermal and mechanical stresses. The Iris Power EL CID test detects shorted laminations and is the accepted world-wide solution for determining maintenance needs.
Current Signature Analysis, Used On Squirrel Cage Induction Motor Rotors